When HSF modules are paralleled, the module with the highest voltage setting automatically becomes the "master." As long as they are in the same voltage range, the other units are slaves, tracking the master voltage setting and equally sharing load current.
Additional Fault Tolerant Solutions with Kepco's Series HSP (hot swap) and HSM (hard wired).
1U: 50W, 100W, 150W -1UR models
Include power factor correction (PFC)
Uses RA 19-1U rack adapter (holds up to 4 sideways-mounted units)
3.3V, 5V, 12V, 15V, 24V, 28V and 48V models.
Four HSF-1UR modules shown in Kepco's Series RA 19-1U Rack Adapter.
3U: 50W, 100W, 150W -PFC models
Use the RA 19(X)B Series Rack adapters (hold various combinations of 1/8-rack (50W and 100W) and 1/6-rack (150W) units. For combinations available refer to the RA 19 Rack Adapter.
3.3V, 5V, 12V, 15V, 24V, 28V and 48V models.
Six 1/6 rack HSF-PFC modules shown in Kepco's Series RA 19-6B Rack Adapter.
3U: 300W, 600W and 1200W/1500W models
Use RA 19-4C Rack Adapter (holds up to four modules)
Remote on-off (standard)
Remote voltage programming capability (standard), voltage measured at front panel test points.
Front panel meter (Optional)
Current sensing signals to monitor individual current output (Optional)
Reset button restores output after sensing an over- or undervoltage condition, thermal overload, or fan malfunction.
HSF 300W Series are offered in 5V, 12V, 15V, 24V, 28V and 48V models.
HSF 600W Series are offered in 12V, 15V, 24V, 28V and 48V models.
HSF 1500W Series are offered in 15V, 24V, 36V, 48V and 60V models.
Four HSF-A 300W, 600W, 1200W/1500W modules shown in Kepco's Series RA 19-4C Rack Adapter.
DC - DC Conversion
All HSF modules are suitable as DC-DC converters, however note that Safety Agency approvals are valid only for a-c input.
DC input voltage ranges for HSF models are as follows:
Contact factory for details regarding options not listed on the associated BUY NOW page.
Feature
Description
Available on Models
Suffix
Meter
Adds front panel meter which displays either voltage or current using a front panel mode switch and includes external current monitoring.
HSF 300W, 600W and 1500W, HSF A 300W and 600W
M AM
Meter + 0V Functionality
Adds front panel meter and also allows output voltage adjustment down to 0V (logic 0, 0 to -0.4V d-c) while maintaining full functionality for LED, alarm relay and meter.
HSF 300W and 600W, HSF A 300W and 600W
MZ AMZ
Current Monitor
Allows current monitoring via an internal sense resistor. (This is standard on 300W, 600W and 1200/1500W models.)
HSF 50W, 100W, and 150W (-PFC and -1UR)
C
Improved Efficiency
Offers improved efficiency, lighter weight and a 50W, 28V Model.
HSF 50W, 100W, and 150W (-PFC and -1UR)
T
Remote On-Off
Allows remote on-off control. (This is standard on 300W, 600W and 1200/1500W models).
HSF 50W, 100W, and 150W (-PFC and -1UR)
X
Current Monitor, Remote On-Off
Includes both current monitoring and remote on-off.
HSF 50W, 100W, and 150W (-PFC and -1UR)
Y
MIL-STD-461 Compliance
Includes compliance to MIL-STD-461.
All (except legacy models)
(See note)
Environmental Compliance
Includes reduced susceptibilityto shock, vibration, temperature, humidity and fungus.
All (except legacy models)
(See note)
NOTE: Select MIL-STD-461 or Environmental compliance options using Quote Request form.