bipolar d-c power, 100, 200, 400 Watts
- Full 4-quadrant operation
- Source and sink 100% of their current rating.
- Separate control circuits for voltage and current with automatic crossover to current and voltage limits.
- Zeroable preamplifier available for scaling and summing external signals.
- Option to drive capacitive loads up to 10mF
- Option to drive magnets up to 1 Henry
- Optional digital displays.
- Optional BIT 4886 provides 16-bit IEEE 488.2 talk- listen control with SCPI support.
- Optional BIT 802E provides ethernet control either through a web page or by using SCPI commands via Telnet.
- Optional BIT TMA-27 connect BOP to Kepco's single-address multiple instrument serial bus for long range (>300m) control from IEEE 488.2, RS 232 or VXI-based hosts.
- Optional BIT 488B or BIT 488D offer listen-only GPIB support in binary or Hex format.
d-c bipolar power, 1KW
- Source & sink, 4 quadrant operation.
- Fast analog programming.
- Precision stabilization: 0.001% source, 0.002% load.
- Digital programming.
- Built-in arbitrary waveform generator.
DC Electronic Loads for testing power sources: batteries, power supplies, generators, chargers, fuel cells, etc.
- Front panel controls and indicators for Amps, Volts and KW
- Computer operated LabVIEW capable
- Constant current, voltage, power, resistance, conductance and short circuit modes
- Readback voltage, current, power and load status
- Optional Ethernet Control in addition to standard USB and RS 232
- Optional GPIB Control in addition to USB and RS 232
- Comprehensive SCPI command set
- Monitor load current via computer or analog output
- Use unique test patterns from Arbitrary Waveform Generator via external analog input
- Remote voltage sense eliminates error caused by voltage drop in test leads
- Transient capability, 50 microseconds to 10 seconds
- Repeating transients, repeating every 100 uS to 10 sec, from 2 to 10,000 times
- Programmable leading/trailing ramps on output changes, from 100 uS to 10 seconds
- Up to 60KW into one 8 ft. rack
Hot-swappable 3U 50W/100W/150W plug-in power supplies for N+1 fault-tolerant power systems
Hot-swappable 3U 300W/600W/1200W/1500W plug-in power supplies for N+1 fault-tolerant power systems
- Built-in forced current sharing and or-ing diodes
- Local voltage control trimming from front panel.
- Built-in EMI filter; conducted noise below FCC and VDE 0871 Class B requirements.
- Separate remote error sense terminals: (all except 1200W/1500W models)
- Individual current monitor (option)
- Peak Current capability on some 24V models for motor-start or other applications requiring brief current surge; these 24V models include thermal protection.
- Built-in alarm relay provides either normally open or normally closed for external failure indication.
- Safety: Designed to meet UL: 60950; CSA:C22.2 60950; TUV: EN60950 (a-c input only).
- Units are CE marked per Low Voltage Directive (LVD),73/23/EEC and 93/68/EEC.
- Bellcore Requirements: Designed to meet NEBS GR-63-CORE. Certification passed: RA 19-6B with six HSF 150W units tested per GR-63-CORE, Level 4 (Earthquake and office vibration).
- Remote voltage control of 300W, 600W, 1200W/1500W modules via trimpot or voltage source.
- Front panel meter optional feature (300W, 600W, 1200W/1500W Models only).
Linear low-noise power supplies respond very quickly and precisely to voltage and current setting instructions from either GPIB (IEEE 488.2) or front panel keypad.
- Linear control for low noise: 100 micro-volts typical in voltage mode
- High precision: 0.0005% source effect {regulation} in voltage mode.
- Voltage and current control with equivalent performance.
- A high speed mode allows fast-recovery current-controlled stabilization into a varying load.
- Overvoltage and overcurrent settings individually programmed by the front panel keypad or remotely by the bus with a programmable delay to allow for reactive-load transients.
- Overvoltage crowbar to protect sensitive loads.
- Non-volatile storage of programmed sequences or active settings.
- Full talk-listen control from a GPIB (IEEE 488-2) using SCPI language.
- Master-slave series and parallel operation to provide increased capability.
- Local control: Front panel keypad entries are used for setting and adjusting the output. The keypad can be used to execute commands directly or to introduce a program to be run later or cycled.
Precision ineractive control, 200 Watts
- Plug-in construction.
- Up to nine 200-watt power supplies in a 4U housing.
- Optional GPIB interface connects (8) eight MST modules to a single GPIB (IEEE 488.2) address with the capacity to control up to 19 additional power supplies.
- Switch-mode conversion, linear post regulator.
- Wide range a-c input: 88-264V a-c with built-in power factor correction (PFC).
- Forced current sharing for N+1 redundancy connection.
JQE bench-top power supplies: systems-type voltage stabilizers with current limiting: 100 watts in a 1/4-rack package, 250-500 watts in a 1/2-rack package, and 1000 watts in a full-rack package.
- 10 turn voltage control for exceptional resolution.
- Analog output control by resistance: 1000W/Volt; or by a voltage delivering 0-1mA.
- Digital listen only control using SN-series digital interfaces.
- Current limited, front panel control (not programmable) 10%-105% Io max.
- JQE can control current with an external current-sense resistor.
|
|
Rectangular voltage/current operating boundaries, 2400 Watts
- GPIB & isolated analog controls standard on all models.
- LAN control optional, replaces standard RS 232 interface.
- VXI plug&play, LabView and IVI-COM drivers.
- Control via web browser using LAN interface.
- True 1U height - full power operation with no spacing between units.
- 200-240V a-c input with active PFC.
- Optional Rapid Output Discharge Circuit (RODC)
Voltage, current and power-limited operating boundaries, 1200 Watts
- GPIB & isolated analog controls standard on all models.
- LAN control optional, replaces standard RS 232 interface.
- VXI plug&play, LabView and IVI-COM drivers.
- Control via web browser using LAN interface.
- True 1U height - full power operation with no spacing between units.
- Wide range a-c input with active PFC.
- Optional Rapid Output Discharge Circuit (RODC)
automatic crossover, low-profile, high-performance, low-cost programmable power supplies:
750W 1U 1/2 rack 1500W 1U full rack 3000W 2U full rack
- Constant Voltage/Constant Current with automatic crossover
- Switch mode topology for cool, efficient operation, speed control fan for low noise operation
- RS 485 and isolated analog programming included on all models
- Optional LAN interface (E suffix models)
- Optional GPIB interface (G suffix models)
- Front to back air flow allows full power operation without spacers between supplies
- Wide-range a-c input, 100-240V a-c, 50/60Hz with PFC
- Up to 5 units in parallel and 2 units in series, equipped with active current sharing.
- CE Mark approved.
- Approved to LXI Version 1.4, Device Specification 2011
Single output switcher, current-sharing for parallel redundant N+1 hot swap operation 1000W, 1500W
- Remote sensing (0.5V for 3.3 and 5V models, 0.8V for all others).
- Control/programming of voltage channel, current limit, overvoltage setpoint.
- Set point monitors for voltage and current permit on-line adjustment of output limits.
- Switch selectable Bellcore-type current "walk-in" characteristic for battery charger applications.
- Front panel status indicators, duplicated by form C relay contact status flags at rear panel connector: POWER, DC FAIL, OVERTEMP, FAN FAIL.
- Safety Agency Approvals: Recognized component with SELV output per UL 1950, CSA 950, VDE IEC 950/EN 60950 for a-c mains operation.
- 5" x 5" crossection plug-ins meet EIA standard for 3U height. Fit three abreast in EIA standard 19" equipment racks (four abreast in 24" racks).
- HSP are fully protected for any overload including a short circuit.
- Remote control via one of two isolated TTL-level signals, one normally high and the other normally low.
- Meet all EN 50082-2 (heavy industrial) immunity levels including mains lightning surge
Up to four hot-swappable 1U 50W/100W/150W plug-in power supplies in 19-inch rack for N+1 fault-tolerant power systems
>
- Built-in forced current sharing and or-ing diodes
- Built-in EMI filter; conducted noise below FCC and VDE 0871 Class B requirements.
- Separate remote error sense terminals
- Peak Current capability on some 24V models for motor-start or other applications requiring brief current surge; these 24V models include thermal protection.
- Built-in alarm relay provides either normally open or normally closed for external failure indication.
- Safety: Designed to meet UL: 60950; CSA:C22.2 60950; TUV: EN60950 (a-c input only).
- Units are CE marked per Low Voltage Directive (LVD),73/23/EEC and 93/68/EEC.
- Bellcore Requirements: Designed to meet NEBS GR-63-CORE. Certification passed: RA 19-6B with six HSF 150W units tested per GR-63-CORE, Level 4 (Earthquake and office vibration).
D-c modular power 300, 600, 1000, 1500 Watts
- Remote Programmable Output: included on 1000W, 1500W models (-PV option on 300W, 600W)
- Limited lifetime warranty.
- UL 508 approved.
- Small Size.
- Semi F47 Compliant (high line a-c).
- Universal input (85-265V a-c).
bipolar d-c power, 100, 200, 400 Watts
- Linear programmable power in five sizes to 1000 watts.
- Low noise, high speed linear precision control.
- Voltage and current stabilization.
- 10-turn panel controls offer exceptional resolution.
- User-selectable capacitorless output for fast analog programming or quick recovery current-mode operation.
- User selectable fast or conventional modes of operation. Use fast-mode for rapid response to programmed instructions or for quick response in current mode to load changes.
- Voltage and current modes with full and equal control over the output in both modes.
- Multi-terminal user port allows the ATE to be configured by arranging the jumpers on a mating plug, PC-12.
- Full zeroing and full-scale calibration for both the voltage and current control channels.
- Programmable overvoltage crowbar. Can be manually set from the panel or programmed with a 0-10V analog signal.
- Optically isolated input-output to interconnect multiple power supplies.
- Uncommitted amplifiers to manipulate arbitrary control signals into the required 0-10V needed to program ATE. Two provided. Can be used for scaling and summing.
- Digital control through SN-series IEEE-488 interfaces.
|