NOTE: This procedure is only valid for Firmware Version 3.22 and higher.
  • Set the MODE to OFF (CI, CR, CV and CP indicators all off) as follows:
    • Verify that the load is disengaged (LOAD pushbutton indicator is green (steady). If not press the LOAD pushbutton the disengage the load.
    • Depress and hold the CONTROL knob for 3 seconds. The LOAD pushbutton indicator goes from green to off. Rotating the CONTROL knob while keeping it depressed sequentially selects the operating mode in the order: CV, CI, CP, CR, CS, SHORT and OFF.
  • Release CONTROL when CI, CR, CV and CP indicators are all off.
  • Momentarily depress the LOAD pushbutton (illumination changes to blinking green).
  • Rotate CONTROL counterclockwise until UEr shows in AMPS display, and Firmware Version shows in VOLTS display). For Firmware Versions 3.87 and higher a suffix (e.g., B3 or C) shows in KW display.

    NOTE: If UEr is not displayed, the unit is either a Unit Revision 1 or 2. If Unit Revision is unknown, use Firmware Version 3.12 manual. The only differences between units with Firmware Versions 1.232 and 3.12 are Master/Slave startup and fan operation.

  • To exit, momentarily depress LOAD pushbutton to restore OFF mode (none of the mode LEDs are illuminated and the LOAD pushbutton illumination is steady green).

PRODUCT SUPPORT SURVEY
This page was helpful This page was NOT helpful
COMMENTS
If you would like a reply, please
include your E-Mail Address (Optional):

PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com